PMID- 37447682 OWN - NLM STAT- MEDLINE DCOM- 20230717 LR - 20230718 IS - 1424-8220 (Electronic) IS - 1424-8220 (Linking) VI - 23 IP - 13 DP - 2023 Jun 22 TI - Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test. LID - 10.3390/s23135832 [doi] LID - 5832 AB - In recent years, there has been an exponential increase in the number of devices developed to measure or estimate physical exercise. However, before these devices can be used in a practical and research environment, it is necessary to determine their validity and reliability. The purpose of this study is to test the validity and reliability of a load cell sensor-based device (LC) for measuring the peak force (PFr) and the rate of force development (RFD) during the isometric mid-thigh pull (IMTP) test, using a force plate (FP) as the gold standard. Forty-two undergraduate sport science students (male and female) participated in this study. In a single session, they performed three repetitions of the IMTP test, being tested simultaneously with an LC device and a Kistler force platform (FP). The PFr and RFD data were obtained from the force-time curve of the FP and compared with the LC data, provided automatically by the software of the device (Smart Traction device(c)). The mean difference between the results obtained by the LC device and the gold-standard equipment (FP) was not significantly different (p > 0.05), for both PFr and RFD, which suggests the validity of the ST results. Bland-Altman analysis showed a small mean difference in PFr = 1.69 N, upper bound = 47.88 N, and lower bound = -51.27 N. RFD showed that the mean difference was -5.27 N/s, upper limit = 44.36 N/s, and lower limit = -54.91 N/s. Our results suggest that the LC device can be used in the assessment of the isometric-mid-thigh-pull test as a valid and reliable tool. It is recommended that this device's users consider these research results before putting the ST into clinical practice. FAU - Montoro-Bombu, Raynier AU - Montoro-Bombu R AUID- ORCID: 0000-0002-2642-945X AD - University of Coimbra, Research Unit for Sport and Physical Activity (CIDAF), Faculty of Sport Sciences and Physical Education, 3040-248 Coimbra, Portugal. FAU - Gomes, Beatriz Branquinho AU - Gomes BB AUID- ORCID: 0000-0003-2885-7666 AD - University of Coimbra, Research Unit for Sport and Physical Activity (CIDAF), Faculty of Sport Sciences and Physical Education, 3040-248 Coimbra, Portugal. FAU - Santos, Amandio AU - Santos A AUID- ORCID: 0000-0003-1033-6985 AD - University of Coimbra, Research Unit for Sport and Physical Activity (CIDAF), Faculty of Sport Sciences and Physical Education, 3040-248 Coimbra, Portugal. FAU - Rama, Luis AU - Rama L AUID- ORCID: 0000-0002-9619-8618 AD - University of Coimbra, Research Unit for Sport and Physical Activity (CIDAF), Faculty of Sport Sciences and Physical Education, 3040-248 Coimbra, Portugal. LA - eng PT - Journal Article DEP - 20230622 PL - Switzerland TA - Sensors (Basel) JT - Sensors (Basel, Switzerland) JID - 101204366 SB - IM MH - Humans MH - Male MH - Female MH - *Thigh MH - Reproducibility of Results MH - *Muscle Strength MH - Isometric Contraction MH - Exercise Test/methods PMC - PMC10346244 OTO - NOTNLM OT - force OT - force-time curve OT - peak force OT - rate of force development OT - strength COIS- The authors declare no conflict of interest. EDAT- 2023/07/14 13:06 MHDA- 2023/07/17 06:42 PMCR- 2023/06/22 CRDT- 2023/07/14 01:24 PHST- 2023/04/27 00:00 [received] PHST- 2023/06/09 00:00 [revised] PHST- 2023/06/21 00:00 [accepted] PHST- 2023/07/17 06:42 [medline] PHST- 2023/07/14 13:06 [pubmed] PHST- 2023/07/14 01:24 [entrez] PHST- 2023/06/22 00:00 [pmc-release] AID - s23135832 [pii] AID - sensors-23-05832 [pii] AID - 10.3390/s23135832 [doi] PST - epublish SO - Sensors (Basel). 2023 Jun 22;23(13):5832. doi: 10.3390/s23135832.