PMID- 37576100 OWN - NLM STAT- PubMed-not-MEDLINE LR - 20231031 IS - 0971-6203 (Print) IS - 1998-3913 (Electronic) IS - 0971-6203 (Linking) VI - 48 IP - 2 DP - 2023 Apr-Jun TI - Multivariate Analysis of Effective Dose and Size-Specific Dose Estimates for Thorax and Abdominal Computed Tomography. PG - 210-218 LID - 10.4103/jmp.jmp_102_22 [doi] AB - The study aimed to compute the effective dose (E) and size-specific dose estimate (SSDE) of routine adult patients undergoing thorax and abdominal computed tomography (CT) imaging and to present their multivariate analysis. All adult thorax and abdominal CT examinations conducted from March 2022 to June 2022 were prospectively included in this study. The Water Equivalent Diameter (D(w)) and SSDE of all the examinations were computed from CT dose index volume (CTDI(vol)) and Dose length product (DLP) displayed on the dose report in the CT console. The multivariate statistical analysis was performed to investigate the correlation of SSDE and E on CTDI(vol), D(w) area of the region of interest (ROI) (Area(ROI)), body mass index (BMI), conversion factor (f(size)) and hounsfield (HU(mean)) number in the ROI at 95% level of significance (P < 0.05). The linear regression analysis was performed to investigate the dependence of SSDE and E on other parameters for both abdominal and thorax patients. A total number of 135 (Abdomen = 61 and Thorax = 74) measurements were performed. The mean value of effective dose for abdomen and thorax patients was found to be 7.17 +/- 3.94 and 4.89 +/- 2.16 mSv, respectively. The SSDE was observed to be 13.24 +/- 3.61 and 13.04 +/- 3.61 mGy for thorax and abdomen respectively. The multivariate analysis suggests that SSDE for abdominal CT is found significantly dependent on CTDI(vol), D(w) and f(size) with P < 0.05 and E is found to be significantly dependent on DLP, Area(ROI), D(w) and f(size) at 95% level of confidence for abdominal CT imaging. SSDE for thorax CT was found significantly dependent on BMI, CTDI(vol), HU(mean), D(w) and f(size) at 95% level of confidence. Furthermore, E was observed dependent on DLP at P < 0.05. The linear regression analysis also shows that E is strongly correlated with DLP (r = 1.0) for both thorax and abdominal CT, further the SSDE was observed strongly correlated with CTDI(vol) with r = 0.79 and r = 0.86 for abdomen and thorax CT respectively. A strong correlation was observed between BMI and for D(w) abdominal CT imaging (r = 0.68). The mean value of SSDE for thorax is slightly greater than abdomen. The average value of effective dose for abdomen and thorax measurements was found to be 7.17 +/- 3.94 and 4.89 +/- 2.16 mSv and , correspondingly. SSDE for both abdomen and thorax CT is significantly dependent on CTDI(vol), D(w) and f(size) at 95% level of confidence. The strong correlation was also observed E on DLP and SSDE on CTDI(vol) for both Abdomen and Thorax CT. The strong dependence of D(w) on BMI (r = 0.68) is due to the excessive fat concentration around the stomach and abdomen. CI - Copyright: (c) 2023 Journal of Medical Physics. FAU - Shah, Mudasir Ashraf AU - Shah MA AD - Department of Radiodiagnosis, Faculty of Medicine, Jawaharlal Nehru Medical College, Aligarh Muslim University, Aligarh, Uttar Pradesh, India. FAU - Ahmad, Mehtab AU - Ahmad M AD - Department of Radiodiagnosis, Faculty of Medicine, Jawaharlal Nehru Medical College, Aligarh Muslim University, Aligarh, Uttar Pradesh, India. FAU - Khalid, Saifullah AU - Khalid S AD - Department of Radiodiagnosis, Faculty of Medicine, Jawaharlal Nehru Medical College, Aligarh Muslim University, Aligarh, Uttar Pradesh, India. FAU - Qaseem, Syed M Danish AU - Qaseem SMD AD - Department of Radiodiagnosis, Faculty of Medicine, Jawaharlal Nehru Medical College, Aligarh Muslim University, Aligarh, Uttar Pradesh, India. FAU - Siddiqui, Shaista AU - Siddiqui S AD - Department of Radiodiagnosis, Faculty of Medicine, Jawaharlal Nehru Medical College, Aligarh Muslim University, Aligarh, Uttar Pradesh, India. FAU - Talib, Sayema AU - Talib S AD - Department of Radiodiagnosis, Faculty of Medicine, Jawaharlal Nehru Medical College, Aligarh Muslim University, Aligarh, Uttar Pradesh, India. FAU - Rather, Sajad Ahmed AU - Rather SA AD - Department of Radiological Physics and Bio-Engineering, Sher-i-Kashmir Institute of Medical Sciences, Srinagar, India. FAU - Firdous, Arfat AU - Firdous A AD - Department of Physics, Government Degree College, Sumbal, Jammu and Kashmir, India. LA - eng PT - Journal Article DEP - 20230629 PL - India TA - J Med Phys JT - Journal of medical physics JID - 9441104 PMC - PMC10419744 OTO - NOTNLM OT - Dose length product OT - effective dose OT - size-specific dose estimate OT - water-equivalent diameter COIS- There are no conflicts of interest. EDAT- 2023/08/14 06:41 MHDA- 2023/08/14 06:42 PMCR- 2023/04/01 CRDT- 2023/08/14 04:38 PHST- 2022/11/16 00:00 [received] PHST- 2023/05/10 00:00 [revised] PHST- 2023/05/10 00:00 [accepted] PHST- 2023/08/14 06:42 [medline] PHST- 2023/08/14 06:41 [pubmed] PHST- 2023/08/14 04:38 [entrez] PHST- 2023/04/01 00:00 [pmc-release] AID - JMP-48-210 [pii] AID - 10.4103/jmp.jmp_102_22 [doi] PST - ppublish SO - J Med Phys. 2023 Apr-Jun;48(2):210-218. doi: 10.4103/jmp.jmp_102_22. Epub 2023 Jun 29.