PMID- 37821890 OWN - NLM STAT- MEDLINE DCOM- 20231102 LR - 20231122 IS - 1472-6831 (Electronic) IS - 1472-6831 (Linking) VI - 23 IP - 1 DP - 2023 Oct 11 TI - Positional transfer accuracy of titanium base implant abutment provided by two different scan body designs: an invitro study. PG - 746 LID - 10.1186/s12903-023-03399-9 [doi] LID - 746 AB - BACKGROUND: The variabilities in design and material of scan bodies have a major role in the positional transfer accuracy of implants. The purpose of this invitro study was to compare the 3D transfer accuracy (trueness and precision) of titanium base (TB) abutment position provided by 2 different scan bodies: one-piece scan body (SB) in comparison to two-piece healing abutment and scan peg (HA-SP). METHODS: A maxillary model with a dummy implant in the 2nd premolar (Proactive Tapered Implant; Neoss) was 3D printed and TB (Ti Neolink Mono; Neoss) was tightened on the implant and scanned by using a laboratory scanner (inEos X5; Dentsply Sirona) (reference scan). An SB (Elos Medtech) and an HA-SP (Neoss) were subsequently connected to the implant and were scanned 10 times each by using the same scanner (test scans). All the scans were exported as STL files and imported into CAD software where the TBs were formed. Test scans were superimposed on reference scans for transfer accuracy analysis using 3D metrology software (GOM Inspect; GOM GmbH) in terms of angular deviation in vertical and horizontal directions, linear deviation in each XYZ axis of TBs and total linear deviation in all axes. Statistical analysis was done using independent sample t test. When Levene's test for equality of variances was significant, Welch's t-test was used. (P value < 0.05) RESULTS: Significant differences were found amongst the tested groups in both angular and linear deviation in terms of trueness with less deviation values for the SB group (P < 0.001). For the precision, significant differences were found amongst the tested groups in angular deviation in vertical direction with less deviation value for the SB group compared to HA-SP group (P < 0.001). However, no significant difference was found between the tested groups regarding the angular deviation in horizontal direction (P = 1.000). Moreover, significant differences were found amongst the tested groups in linear deviations with less linear deviations in XYZ axes for SB compared to HA-SP group (P = 0.020, < 0.001, = 0.010 respectively). CONCLUSIONS: SB showed less angular and linear deviation values in the 3D positional transfer of TB than HA-SP indicating higher degree of accuracy of SB. CI - (c) 2023. BioMed Central Ltd., part of Springer Nature. FAU - Ramadan, Rania E AU - Ramadan RE AD - Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt. rania.elsayed.dent@alexu.edu.eg. FAU - Razek, Mahmoud Khamis Abdel AU - Razek MKA AD - Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt. FAU - Mohamed, Faten S AU - Mohamed FS AD - Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt. FAU - Fahmy, Rania A AU - Fahmy RA AD - Department of Oral Medicine and Periodontology, Faculty of Dentistry, Alexandria University, Alexandria, Egypt. FAU - Abd-Ellah, Mervat E AU - Abd-Ellah ME AD - Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt. LA - eng PT - Journal Article DEP - 20231011 PL - England TA - BMC Oral Health JT - BMC oral health JID - 101088684 RN - D1JT611TNE (Titanium) RN - 0 (Dental Implants) SB - IM MH - Humans MH - *Computer-Aided Design MH - Titanium MH - Dental Impression Technique MH - Models, Dental MH - *Dental Implants MH - Imaging, Three-Dimensional PMC - PMC10568787 OTO - NOTNLM OT - Healing abutment-scan peg OT - Meteorology software OT - Positional transfer accuracy OT - Scan body OT - Titanium base abutment COIS- The authors declare no competing interests. EDAT- 2023/10/12 00:43 MHDA- 2023/11/02 12:45 PMCR- 2023/10/11 CRDT- 2023/10/11 23:51 PHST- 2023/03/31 00:00 [received] PHST- 2023/09/09 00:00 [accepted] PHST- 2023/11/02 12:45 [medline] PHST- 2023/10/12 00:43 [pubmed] PHST- 2023/10/11 23:51 [entrez] PHST- 2023/10/11 00:00 [pmc-release] AID - 10.1186/s12903-023-03399-9 [pii] AID - 3399 [pii] AID - 10.1186/s12903-023-03399-9 [doi] PST - epublish SO - BMC Oral Health. 2023 Oct 11;23(1):746. doi: 10.1186/s12903-023-03399-9.