PMID- 3956092 OWN - NLM STAT- MEDLINE DCOM- 19860514 LR - 20190813 IS - 0009-9260 (Print) IS - 0009-9260 (Linking) VI - 37 IP - 1 DP - 1986 Jan TI - The daily reproducibility of large, complex-shaped radiotherapy fields to the thorax and neck. PG - 39-41 AB - A series of patients treated with complex fields to the thorax and neck utilising individually tailored shielding blocks made from low-melting-point alloy (LMPA), were investigated using treatment verification film to identify field placement errors. A total of 19 patients yielded 171 machine verification films, which were analysed. It was found that on 21% of occasions the intended treatment volume was partially shielded, by more than 1 cm, by the lead blocks prescribed to protect the lungs. On half of these occasions (11% of the total), the areas erroneously shielded contained known disease. Suggestions are made for minimising such errors in the future. FAU - Griffiths, S E AU - Griffiths SE FAU - Pearcey, R G AU - Pearcey RG LA - eng PT - Journal Article PT - Research Support, Non-U.S. Gov't PL - England TA - Clin Radiol JT - Clinical radiology JID - 1306016 SB - IM MH - Head and Neck Neoplasms/diagnostic imaging/*radiotherapy MH - Hodgkin Disease/radiotherapy MH - Humans MH - Lung/diagnostic imaging MH - Mediastinum/diagnostic imaging MH - *Radiation Protection MH - Radiography MH - Thoracic Neoplasms/diagnostic imaging/*radiotherapy EDAT- 1986/01/01 00:00 MHDA- 1986/01/01 00:01 CRDT- 1986/01/01 00:00 PHST- 1986/01/01 00:00 [pubmed] PHST- 1986/01/01 00:01 [medline] PHST- 1986/01/01 00:00 [entrez] AID - S0009-9260(86)80163-5 [pii] AID - 10.1016/s0009-9260(86)80163-5 [doi] PST - ppublish SO - Clin Radiol. 1986 Jan;37(1):39-41. doi: 10.1016/s0009-9260(86)80163-5.