PMID- 7760511 OWN - NLM STAT- MEDLINE DCOM- 19950626 LR - 20190825 IS - 0021-4868 (Print) IS - 0021-4868 (Linking) VI - 36 IP - 1 DP - 1995 Jan TI - The use of the handgrip maneuver to identify left ventricular diastolic function abnormalities by Doppler echocardiography in patients with coronary artery disease. PG - 23-8 AB - Doppler echocardiography accurately identifies diastolic dysfunction through the assessment of transmitral flow patterns during the application of the handgrip (HG) maneuver. In this study, 45 normal control patients (mean age 46 +/- 9, group A) and 13 patients with coronary artery disease (CAD) (mean age 51 +/- 6, group B) were involved. The effects of handgrip maneuver on transmitral flow patterns were studied by Doppler echocardiography. Group B patients had higher peak late diastolic filling velocities (A), lower peak early (E) to late diastolic filling velocity ratios (E/A) and longer isovolumic relaxation times (IVRT) compared to group A. On the other hand, systolic blood pressure (SBP), heart rate (HR) and peak E velocity (E) did not change significantly (p > 0.05) in either group, at rest. During the supine handgrip maneuver, NR (mean +/- standard error of mean, +21 +/- 13%, p < 0.05) and SBP (+21 +/- 9%, p < 0.05) increased significantly in both group A and group B (+21 +/- 13%, p < 0.05, +22 +/- 15%, p < 0.05, respectively). In group B, E/A ratio (-28 +/- 7%) decreased significantly (p < 0.05) compared to group A (-20 +/- 6%), as a consequence of significantly increased peak A velocity in group B (+7 +/- 5%) compared to group A (+6 +/- 3%, p < 0.05). Deceleration time decreased significantly in both groups (-10 +/- 6% vs -9 +/- 6%, p < 0.05). Isovolumic relaxation time (IVRT) significantly increased in both groups (+18 +/- 7% vs +16 +/- 6%, p < 0.001).(ABSTRACT TRUNCATED AT 250 WORDS) FAU - Tavli, T AU - Tavli T AD - Department of Cardiology, Medical School of Selcuk University, Konya, Turkey. FAU - Cin, V G AU - Cin VG FAU - Tavli, V AU - Tavli V FAU - Wong, M AU - Wong M LA - eng PT - Clinical Trial PT - Journal Article PL - Japan TA - Jpn Heart J JT - Japanese heart journal JID - 0401175 SB - IM MH - Adult MH - Aged MH - Aged, 80 and over MH - Blood Flow Velocity MH - Coronary Disease/*diagnostic imaging/*physiopathology MH - *Diastole MH - *Echocardiography, Doppler MH - Exercise Test MH - Female MH - *Hand Strength MH - Humans MH - Male MH - Middle Aged MH - Reproducibility of Results MH - *Ventricular Function, Left EDAT- 1995/01/01 00:00 MHDA- 1995/01/01 00:01 CRDT- 1995/01/01 00:00 PHST- 1995/01/01 00:00 [pubmed] PHST- 1995/01/01 00:01 [medline] PHST- 1995/01/01 00:00 [entrez] AID - 10.1536/ihj.36.23 [doi] PST - ppublish SO - Jpn Heart J. 1995 Jan;36(1):23-8. doi: 10.1536/ihj.36.23.