PMID- 7911562 OWN - NLM STAT- MEDLINE DCOM- 19940714 LR - 20131121 IS - 0375-9393 (Print) IS - 0375-9393 (Linking) VI - 60 IP - 1-2 DP - 1994 Jan-Feb TI - [Post-tetanic count after 50 and 100 Hz tetanic stimulation for monitoring deep neuromuscular blockade with vecuronium]. PG - 49-53 AB - For monitoring of vecuronium profound neuromuscular blockade post-tetanic count (PTC) following tetanic stimulation at frequency of 50 and 100 Hz was employed in 25 ASA I-II patients submitted to elective surgery, to evaluate the differences between the two patterns of stimulation and the possible clinical utility of the latter pattern of stimulation. The drugs employed for anaesthesia were: diazepam 0.15 mg kg-1 in premedication, thiopental 4-5 mg kg-1 for induction, suxamethonium 1.5 mg kg-1 for tracheal intubation. Anaesthesia was maintained with N2 + O2 (2:1). Analgesia was obtained with fentanyl at usual doses, and muscular relaxation with vecuronium. The ulnar nerve was stimulated at the wrist with Digistim III Plus and the responses evaluated by tactile method. The pattern of stimulation used was a cyclic one, as described by Howardy Hansen et al. The first dose of vecuronium (0.06 mg kg-1) was administered at recovery from suxamethonium (clinically evaluated) and the other doses (0.06 mg kg-1) when the third response to a train of four appeared. The results show that the PTC following 100 Hz tetanus was greater than the PTC following 50 Hz tetanic stimulation (P < 0.01). The results also show that PTC following 100 Hz tetanus leads to underestimate neuromuscular blockade; yet maybe it has any clinical employment in selected surgical situations such as middle ear and eye surgery, microvascular surgery, neurosurgery. FAU - Barbone, G AU - Barbone G AD - Istituto di Anestesiologia e Rianimazione, Universita di Bari. FAU - Traversa, M AU - Traversa M FAU - Fiore, T AU - Fiore T LA - ita PT - Clinical Trial PT - Comparative Study PT - Controlled Clinical Trial PT - English Abstract PT - Journal Article TT - Il conteggio post-tetanico dopo tetano a 50 e a 100 Hz nel monitoraggio del blocco neuromuscolare profondo da vecuronio. PL - Italy TA - Minerva Anestesiol JT - Minerva anestesiologica JID - 0375272 RN - 7E4PHP5N1D (Vecuronium Bromide) SB - IM MH - Adolescent MH - Adult MH - Aged MH - Electric Stimulation/*methods MH - Female MH - Humans MH - Male MH - Middle Aged MH - Muscle Contraction/*physiology MH - *Nerve Block MH - Neuromuscular Junction MH - *Vecuronium Bromide EDAT- 1994/01/01 00:00 MHDA- 1994/01/01 00:01 CRDT- 1994/01/01 00:00 PHST- 1994/01/01 00:00 [pubmed] PHST- 1994/01/01 00:01 [medline] PHST- 1994/01/01 00:00 [entrez] PST - ppublish SO - Minerva Anestesiol. 1994 Jan-Feb;60(1-2):49-53.