PMID- 9044419 OWN - NLM STAT- MEDLINE DCOM- 19970709 LR - 20190726 IS - 0031-9155 (Print) IS - 0031-9155 (Linking) VI - 42 IP - 2 DP - 1997 Feb TI - Single-and dual-energy CT with monochromatic synchrotron x-rays. PG - 371-87 AB - We explored the potential for clinical research of computed tomography (CT) with monochromatic x-rays using the preclinical multiple energy computed tomography (MECT) system at the National Synchrotron Light Source. MECT has a fixed, horizontal fan beam with a subject apparatus rotating about a vertical axis; it will be used for imaging the human head and neck. Two CdWO4-photodiode array detectors with different spatial resolutions were used. A 10.5 cm diameter acrylic phantom was imaged with MECT at 43 keV and with a conventional CT (CCT) at 80 kVp: spatial resolution approximately equal to 6.5 line pairs (lp)/cm for both; slice height, 2.6 mm for MECT against 3.0 mm for CCT; surface dose, 3.1 cGy for MECT against 2.0 cGy for CCT. The resultant image noise was 1.5 HU for MECT against 3 HU for CCT. Computer simulations of the same images with more precisely matched spatial resolution, slice height and dose indicated an image-noise ratio of 1.4:1.0 for CCT against MECT. A 13.5 cm diameter acrylic phantom imaged with MECT at approximately 0.1 keV above the iodine K edge and with CCT showed, for a 240 micrograms I ml-1 solution, an image contrast of 26 HU for MECT and 13 and 9 HU for the 80 and 100 kVp CCT, respectively. The corresponding numbers from computer simulation of the same images were 26, 12, and 9 HU, respectively. MECT's potential for use in clinical research is discussed. FAU - Dilmanian, F A AU - Dilmanian FA AD - Brookhaven National Laboratory, Upton, NY 11973-5000, USA. FAU - Wu, X Y AU - Wu XY FAU - Parsons, E C AU - Parsons EC FAU - Ren, B AU - Ren B FAU - Kress, J AU - Kress J FAU - Button, T M AU - Button TM FAU - Chapman, L D AU - Chapman LD FAU - Coderre, J A AU - Coderre JA FAU - Giron, F AU - Giron F FAU - Greenberg, D AU - Greenberg D FAU - Krus, D J AU - Krus DJ FAU - Liang, Z AU - Liang Z FAU - Marcovici, S AU - Marcovici S FAU - Petersen, M J AU - Petersen MJ FAU - Roque, C T AU - Roque CT FAU - Shleifer, M AU - Shleifer M FAU - Slatkin, D N AU - Slatkin DN FAU - Thomlinson, W C AU - Thomlinson WC FAU - Yamamoto, K AU - Yamamoto K FAU - Zhong, Z AU - Zhong Z LA - eng PT - Comparative Study PT - Journal Article PT - Research Support, U.S. Gov't, Non-P.H.S. PL - England TA - Phys Med Biol JT - Physics in medicine and biology JID - 0401220 RN - 0 (Acrylates) RN - 9679TC07X4 (Iodine) SB - IM MH - Acrylates MH - Animals MH - Computer Simulation MH - Equipment Design MH - Head MH - Humans MH - Iodine MH - Neck MH - *Phantoms, Imaging MH - Rabbits MH - Synchrotrons MH - Tomography, X-Ray Computed/*instrumentation MH - X-Rays EDAT- 1997/02/01 00:00 MHDA- 1997/02/01 00:01 CRDT- 1997/02/01 00:00 PHST- 1997/02/01 00:00 [pubmed] PHST- 1997/02/01 00:01 [medline] PHST- 1997/02/01 00:00 [entrez] AID - 10.1088/0031-9155/42/2/009 [doi] PST - ppublish SO - Phys Med Biol. 1997 Feb;42(2):371-87. doi: 10.1088/0031-9155/42/2/009.