PMID- 9562077 OWN - NLM STAT- MEDLINE DCOM- 19980714 LR - 20190914 IS - 1053-1807 (Print) IS - 1053-1807 (Linking) VI - 8 IP - 2 DP - 1998 Mar-Apr TI - Reproducibility study of left ventricular measurements with breath-hold cine MRI using a semiautomated volumetric image analysis program. PG - 467-72 AB - The reproducibility of a semiautomated method of volumetric analysis allowing estimates of left ventricular (LV) parameters in approximately 5 minutes of analysis time is reported. Twenty normal volunteers underwent cine breath-hold cardiac MRI on two occasions with two observers using this new semiautomated method to estimate LV parameters. Reproducibility of this technique was comparable to published data with a variability of less than approximately 10% for all LV parameters calculated. Using this technique, the 95% confidence limits for change for left ventricular end diastolic volume (LVEDV) = +/-15 ml, left ventricular end systolic volume (LVESV) = +/-8 ml, LV mass = +/-24 g, and left ventricular ejection fraction (LVEF) = +/-6%. This new method also compared favorably to established manual methods. This new method permits estimation of LV parameters with acceptable reproducibility in a time that may permit routine quantitation of cardiac MR studies. FAU - Butler, S P AU - Butler SP AD - Division of Medical Imaging, St. George Hospital, Sydney, Australia. FAU - McKay, E AU - McKay E FAU - Paszkowski, A L AU - Paszkowski AL FAU - Quinn, R J AU - Quinn RJ FAU - Shnier, R C AU - Shnier RC FAU - Donovan, J T AU - Donovan JT LA - eng PT - Journal Article PL - United States TA - J Magn Reson Imaging JT - Journal of magnetic resonance imaging : JMRI JID - 9105850 SB - IM MH - Adult MH - Automation MH - Evaluation Studies as Topic MH - Female MH - Humans MH - Image Processing, Computer-Assisted/*methods MH - Linear Models MH - *Magnetic Resonance Imaging, Cine MH - Male MH - Middle Aged MH - Observer Variation MH - Reproducibility of Results MH - *Ventricular Function, Left EDAT- 1998/04/30 00:00 MHDA- 1998/04/30 00:01 CRDT- 1998/04/30 00:00 PHST- 1998/04/30 00:00 [pubmed] PHST- 1998/04/30 00:01 [medline] PHST- 1998/04/30 00:00 [entrez] AID - 10.1002/jmri.1880080230 [doi] PST - ppublish SO - J Magn Reson Imaging. 1998 Mar-Apr;8(2):467-72. doi: 10.1002/jmri.1880080230.